ISBN: 9783330051331 - method development and validation for voriconazole estimation: rp-hplc and uv spectrophotometric methods in bulk and pharmaceutical formulations (7 risultati)

- Brossura
Da: California Books, Miami, FL, U.S.A.California Books
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 47,08
EUR 2,69 spedizioneSpedito in U.S.A.Quantità: Più di 20 disponibili
Condizione: New.
Altre immagini- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 39,45
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Method Development and Validation for Voriconazole Estimation | RP-HPLC and UV Spectrophotometric Methods in Bulk and Pharmaceutical Formulations | Yarguntla Srinivasa Rao (u. a.) | Taschenbuch | Englisch | 2024 | LAP LAMBERT Academic Publishing | EAN 9783330051331 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Brossura
- Print on Demand
Da: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 47,14
Spedizione gratuitaSpedito in U.S.A.Quantità: Più di 20 disponibili
PAP. Condizione: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Brossura
- Print on Demand
Da: PBShop.store UK, Fairford, GLOS, Regno UnitoPBShop.store UK
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 45,72
EUR 3,95 spedizioneSpedito da Regno Unito a U.S.A.Quantità: Più di 20 disponibili
PAP. Condizione: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 43,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 80 pp. Englisch.

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 49,63
EUR 35,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the max determined to be 223 nm. The method exhibited linearity over a concentration range of 5-30 µg/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards.…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 43,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibile
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the ¿max determined to be 223 nm. The method exhibited linearity over a concentration range of 5-30 µg/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.…