Isbn: 9786206146360 - novel algorithms for detection of line outage using pmu (6 risultati)

- Brossura
Da: preigu, Osnabrück, Germaniapreigu
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 58,75
EUR 70,00 spedizioneSpedito da Germania a U.S.A.Quantità: 5 disponibili
Taschenbuch. Condizione: Neu. Novel Algorithms for Detection of Line Outage using PMU | Mehebub Alam (u. a.) | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786206146360 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

- Brossura
Da: Mispah books, Redhill, SURRE, Regno UnitoMispah books
Contatta il venditoreVenditore con 4 stelleCondizione: Nuovo
EUR 130,64
EUR 29,09 spedizioneSpedito da Regno Unito a U.S.A.Quantità: 1 disponibili
paperback. Condizione: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Brossura
- Print on Demand
Da: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermaniaBuchWeltWeit Ludwig Meier e.K.
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,90
EUR 23,00 spedizioneSpedito da Germania a U.S.A.Quantità: 2 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The primary aim of this research work is to address the different objectives such as (i) exploitation of the AC model and development of the new objective functions, (ii) utilization of current phasors exclusively instead of voltage phasors which are used by most of the existing researchers, (iii) tackling of PMU outage issues, (iv) incorporation of faulty PMU and measurement uncertainty into the mathematical models, (v) detection of parallel line outage and (vi) ensuring the cost-effectiveness of the developed models. This entire research work is accomplished phase-wise to achieve the objectives mentioned above. Firstly, the voltage phasors are used to develop the TLOD model. Secondly, the current phasors are utilized to solve the transmission line outage detection (TLOD) problem. The detection of parallel line outage is also validated for the first time using current phasor based algorithms. The effectiveness and viability of the proposed TLOD algorithms have been checked on different IEEE benchmark test systems in the MATLAB environment. The performance of the proposed TLOD models has been evaluated by computing the detection accuracy (DA). 156 pp. Englisch.…

- Brossura
- Print on Demand
Da: moluna, Greven, Germaniamoluna
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 55,87
EUR 48,99 spedizioneSpedito da Germania a U.S.A.Quantità: Più di 20 disponibili
Condizione: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. The primary aim of this research work is to address the different objectives such as (i) exploitation of the AC model and development of the new objective functions, (ii) utilization of current phasors exclusively instead of voltage phasors which are used b.…

- Brossura
- Print on Demand
Da: AHA-BUCH GmbH, Einbeck, GermaniaAHA-BUCH GmbH
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 98,14
EUR 30,50 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The primary aim of this research work is to address the different objectives such as (i) exploitation of the AC model and development of the new objective functions, (ii) utilization of current phasors exclusively instead of voltage phasors which are used by most of the existing researchers, (iii) tackling of PMU outage issues, (iv) incorporation of faulty PMU and measurement uncertainty into the mathematical models, (v) detection of parallel line outage and (vi) ensuring the cost-effectiveness of the developed models. This entire research work is accomplished phase-wise to achieve the objectives mentioned above. Firstly, the voltage phasors are used to develop the TLOD model. Secondly, the current phasors are utilized to solve the transmission line outage detection (TLOD) problem. The detection of parallel line outage is also validated for the first time using current phasor based algorithms. The effectiveness and viability of the proposed TLOD algorithms have been checked on different IEEE benchmark test systems in the MATLAB environment. The performance of the proposed TLOD models has been evaluated by computing the detection accuracy (DA).…

- Brossura
- Print on Demand
Da: buchversandmimpf2000, Emtmannsberg, BAYE, Germaniabuchversandmimpf2000
Contatta il venditoreVenditore con 5 stelleCondizione: Nuovo
EUR 68,90
EUR 60,00 spedizioneSpedito da Germania a U.S.A.Quantità: 1 disponibili
Taschenbuch. Condizione: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The primary aim of this research work is to address the different objectives such as (i) exploitation of the AC model and development of the new objective functions, (ii) utilization of current phasors exclusively instead of voltage phasors which are used by most of the existing researchers, (iii) tackling of PMU outage issues, (iv) incorporation of faulty PMU and measurement uncertainty into the mathematical models, (v) detection of parallel line outage and (vi) ensuring the cost-effectiveness of the developed models. This entire research work is accomplished phase-wise to achieve the objectives mentioned above. Firstly, the voltage phasors are used to develop the TLOD model. Secondly, the current phasors are utilized to solve the transmission line outage detection (TLOD) problem. The detection of parallel line outage is also validated for the first time using current phasor based algorithms. The effectiveness and viability of the proposed TLOD algorithms have been checked on different IEEE benchmark test systems in the MATLAB environment. The performance of the proposed TLOD models has been evaluated by computing the detection accuracy (DA).VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 156 pp. Englisch.…